Structural & Safety Calculators

Wall Geometry
Backfill Properties
Wall Resistance
Active Earth Pressure
kPa max at base
Horizontal Force on Wall
kN/m
Overturning Moment
kNm/m
Resisting Moment
kNm/m
FoS Sliding
(target ≥ 1.5)
Base Pressure — Toe
kPa
Base Pressure — Heel
kPa
Stability Status
Drain Provision
Rankine Ka = (1−sin φ)/(1+sin φ). Active pressure diagram: triangular for backfill weight (σh=Ka×γ×z), rectangular for surcharge (σh=Ka×q). Overturning moment about toe. Resisting moment = wall self-weight × arm. FoS overturning ≥2.0, sliding ≥1.5 (BS EN 1997-1). Drainage essential to prevent pore water pressure build-up.
Member Properties
Loading & Service Class
Applied UDL
kN/m
Section Modulus Wx
cm³
Max Bending Moment
kNm
Max Shear Force
kN
Bending Stress Actual
N/mm²
Permissible Stress (Kmod)
N/mm²
Deflection
mm
Deflection Check (span/300)
Shear Check
Eurocode 5 (BS EN 1995-1): Kmod factors for service class and load duration modify permissible stress. SC2/Med-term: Kmod=0.80. Deflection limit: span/300 (inst.) or span/250 (final). Bending check: σm,d ≤ fm,k × Kmod / γM (γM=1.3 timber). This tool provides indicative results — structural engineer to verify.
Fence Geometry
Wind & Site
10-min mean at 10m height
Post Specification
Wind Pressure on Panel
kPa
Bending Moment at Ground
kNm
Required Embedment Depth
m
Post Bending Stress
N/mm²
Concrete Volume per Post
litres
Post Bending Status
Wind pressure q = 0.5 × ρ × V² × Cf × Ce (ρ=1.25 kg/m³ air density, Ce=exposure factor, Cf=force coefficient). Horizontal force per post = q × fence area per post (height × spacing). Embedment depth (propped cantilever in soil): d = √(3×M / (Fb×1.5×L)) where Fb = soil bearing at pile (simplified).
Slope Geometry
Soil Properties
0=dry, 0.50=sat
FoS Infinite Slope
ratio
Required Angle for FoS 1.5
° (if currently failing)
Stability Status
Infinite slope: FoS = (c + (γ×H×cos²β − ru×γ×H)×tan φ) / (γ×H×sinβ×cosβ). Bishop simplified uses circular failure surface — this tool uses a simplified Bishop iteration. For critical slopes, retain a geotechnical engineer and BS EN 1997-1 / CIRIA C580 guidance.
Compliance Standard
Path Geometry
Leave 0 if not a ramp
10
/ 10 Pass
Compliance Criteria Checklist
CriterionValueStatusStandard Rule
Space Parameters
Occupancy Factor Applied
/person
Egress Width Required
m total clear exit width
Fire Egress ComplianceVerify with fire engineer
Assembly Point RecommendationProvide safe dispersal area
Approved Document B (UK): exit width ≥750mm per exit, one exit per 60 persons below 200 persons. IBC 2021 Table 1004.5: occupant load factors by use. Egress width: UK=8mm per person (stairs), 5.3mm (corridors). Always verify with fire engineer and local fire authority for occupied public spaces.